Part No. | Features | VCC(V) | Package |
GF2140 | Low Power 2-Wire Ground Fault Interrupter * Directly powered from the AC line * Build-in bridge rectifier * Interface to SCR * Adjustable trip current and time delay * Minimum external components * For two-wire system * Be used in 110V or 220V system | 6.5 Regulated | SOP-8 |
GF4141 | Low power ground fault interrupter * Powered from the AC line * Low quiescent current * Built-in diode rectifier * Direct interface to SCR * Precision sense amplifier * Time delay * For use with 110V or 220V systems | 26 VREG | SOP-8 |
GF4146 | Ground fault interrupter * For Two-Wire ALCI and RCD Applications * Precision Sense Amplifier and Bandgap Reference * Built-in AC Rectifier * Direct DC Coupled to Sense Coil * Low-Voltage SCR Disable * Adjustable Sensitivity * Built-in Noise Filter * SCR Gate Driver * Minimum External Components * Ideal for 120V or 220V Systems | 16 | SOT-26 |
GF4147 | Ground fault interrupter * For GFCI and RCD Applications * Built-in AC Rectifier * Built-in Noise Filter * Low-Voltage SCR Disable * Direct DC Coupled to Sense Coil * SCR Gate Driver * Adjustable Sensitivity * Low Quiescent Current * Minimum External Components * Ideal for 120V or 220V Systems | 12.7 VREG | SOT-26 |
GF4149 | Ground fault interrupter * Precision Sense Amplifier and Bandgap Reference * Low-VOS Offset * Built-in Noise Filter * High-Current SCR Gate Driver * Adjustable Sensitivity * Low Quiescent Current * Minimum External Components * Ideal for 120V or 220V Systems | 14 VREG | SOT-26 |
M54133 | Earth Leakage Current Detector( EIOH1&2 = ±20%) * Improvement of ability against unwanted tripping by lightning-surge and lightning impulse. Two times counting system adopted. * Improvement of ability against unwanted tripping by inverter-noise. Built-in operational amplifier (of low current dissipation) for active low-pass filter. Improved high-frequency, high harmonic superposition performance * Internal time delay function * An external capacitor is used to set the delay time. * High input sensitivity: VT=11.5mVrms Typ. * Low-current dissipation (at RIREF=180kΩ) In stand-by condition: IS=610μA Typ. * High stabilities design Adopt the circuits that is not affected by fluctuations of supply voltage/ambient temperature. | 7.0 ~ 12.0 | SOP-16 |
M54133A | Earth Leakage Current Detector * Improvement of ability against unwanted tripping by lightning-surge and lightning impulse. Two times counting system adopted. * Improvement of ability against unwanted tripping by inverter-noise. Built-in operational amplifier (of low current dissipation) for active low-pass filter. Improved high-frequency, high harmonic superposition performance * Internal time delay function * An external capacitor is used to set the delay time. * High input sensitivity: VT=11.5mVrms Typ.
* Low-current dissipation (at RIREF=180kΩ) In stand-by condition: IS=610μA Typ. * High stabilities design Adopt the circuits that is not affected by fluctuations of supply voltage/ambient temperature. | 7.0 ~ 12.0 | SOP-16 SOP-16N |
M54134 | Earth Leakage Current Detector( EIOH1&2 = ±10%) * Improvement of ability against unwanted tripping by lightning-surge and lightning impulse. Two times counting system adopted. * Improvement of ability against unwanted tripping by inverter-noise. Built-in operational amplifier (of low current dissipation) for active low-pass filter. Improved high-frequency, high harmonic superposition performance * Internal time delay function * An external capacitor is used to set the delay time. * High input sensitivity: VT=11.5mVrms Typ. * Low-current dissipation (at RIREF=180kΩ) In stand-by condition: IS=610μA Typ. * High stabilities design Adopt the circuits that is not affected by fluctuations of supply voltage/ambient temperature. | 7.0 ~ 12.0 | SOP-16 SOP-16N |
M54123L | Earth Leakage Current Detector * With good input sensitivity current temperature characteristics * High input sensitivity :VT=6.1mV (Typ.) * Only need low external component count * High noise and surge-proof * Low power dissipation :PD=5mW (Typ.) * May be used both as 100V and 200V. * Wide temperature range : from -20 °C to +80°C | Vz=12.0V (Min) | DIP-8 SOP-8 SIP-8 |
M54123B | Earth leakage current detector * With good input sensitivity current temperature characteristics * High input sensitivity : VT=6.1mV (Typ.) * Only need low external component count * High noise and surge-proof * Low power dissipation : PD=5mW (Typ.) * May be used both as 100V and 200V. * Wide temperature range : from -20°C to +80°C | Vz=12.0V (Min) | SOP-8 |
M54223 | Earth Leakage Current Detector * With good input sensitivity current temperature characteristics * High input sensitivity :VT=6.1mV (Typ.) * Only need low external component count * High noise and surge-proof * Low power dissipation :PD=5mW (Typ.) * May be used both as 100V and 200V. * Wide temperature range : from -20 °C to +80°C | Vs=12.0V (Min) | DIP-8 SOP-8 |
GM1851 | Ground Fault Interrupter * Internal power supply shunt regulator * Externally programmable fault current threshold * Externally programmable fault current integration time * Direct interface to SCR * Operates under line reversal; both load vs line and hot vs neutral * Detects neutral line faults | VZ=26.0 (Typ) | DIP-8 SOP-8 |
GV4145A | Low Power Ground Fault Interrupter * No potentiomenter required * Direct interface to SCR * Supply voltage derived from AC line-26V shunt * Adjustable sensitivity * Grounded neutral fault detection * 450μA quiescent current * I deal for 120V or 220V systems | VZ=26.0 (Typ) | DIP-8 SOP-8 |
M54147 | CMOS leakage protection circuit * AC power supply * Drive SCR, the output pulse width greater than 30ms * Used to detect the A and AC signal * Same higher accuracy for different leakage signal * Excellent immunity to EMC * 110V~220V(50~60Hz) | 4.7~4.9 | SOP-8 |
M54149 | CMOS leakage protection circuit * AC power supply * Drive SCR, the output pulse width greater than 30ms * Used to detect the A and AC signal * Same higher accuracy for different leakage signal * Delay by external capacitor * 110V~220V(50~60Hz) * Width temperature range (TA=-30~+85°C) * Available in SOP14 packages | 4.65~4.95 | SOP-14 |
GV4145-Q | Low Power Ground Fault Interrupter * No potentiomenter required * Direct interface to SCR * Supply voltage derived from AC line-26V shunt * Adjustable sensitivity * Grounded neutral fault detection * 450μA quiescent current * I deal for 120V or 220V systems | VZ=26.0 (Typ) | SOP-8 |